skip to main content


Search for: All records

Creators/Authors contains: "Kurniawan, Jonas F."

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract  
    more » « less
  2. Abstract

    Flexible and stretchable electronics are a logical choice for the recording of biopotentials, due to their improved patient comfort and customizability. There is, however, significant variance in the signal quality received from these electrodes based on material, size, and target recording frequency. Here we develop a methodology based on Electrochemical Impedance Spectroscopy (EIS) and circuit modeling for optimizing electrodes for a specific application. We use EIS to measure the frequency dependent impedance characteristics of gold (Au) and silver/silver chloride (Ag/AgCl) electrodes of different diameters. Additionally, we use a Randles circuit model and perform model fitting with our data to extrapolate results to arbitrary frequencies and diameters. We found that at low frequencies (<1 Hz), Ag/AgCl had lower overall magnitude impedance than Au and at higher frequencies (1–1000 Hz), Au and Ag/AgCl performed similarly. Further, the magnitude impedance of the electrodes decreased linearly as electrode diameter increased. The methodology described in this study can be applicable to any customizable stretchable electronics fabrication process and enables design optimization for a target frequency, electrode size, and material.

     
    more » « less
  3. Abstract

    Here, an unobtrusive, adhesive‐integrated electrode array for continuous monitoring of stomach electric activity is introduced. This patient‐friendly, disposable peel‐and‐stick adhesive device represents an important advancement over existing arrays that require placement of each electrode individually and are thus also labor intensive and are in general more rigid and cumbersome. In comparison to other silver–silver chloride electrodes, this skin conformal array does not require gel and thus can withstand low impedance over the duration of long recordings. Interfacing these electrodes with miniaturized electronic recording and wireless telemetry systems has the potential to enable scalable population health opportunities to perform objective gastrointestinal assessment and optimization of treatment regimens.

     
    more » « less